Wire Rope Inspection
OSHA Removal Criteria
The broken-wire numbers and the three deficiency categories OSHA uses to decide when crane wire rope comes out of service.
Reviewed November 2026 against 29 CFR 1926.1413.
The Three Deficiency Categories
| Category | What is in it | What has to happen |
|---|---|---|
| Category I | Significant distortion of the rope structure: kinking, crushing, unstranding, birdcaging, core failure or steel core protrusion. Significant corrosion. Electric arc or heat damage. Improperly applied or damaged end connections | The competent person decides right away whether it is a safety hazard. If it is, the rope is not used until it is replaced or the damaged section is removed |
| Category II | Visible broken wires at the limits below, or a diameter reduction of more than 5% from nominal | The rope is not used until it is replaced, the damaged section is cut out, or the employer meets the rope manufacturer's own removal criterion (or one the manufacturer has approved in writing for that rope) |
| Category III | Core protrusion or other distortion showing core failure in rotation-resistant rope, prior electrical contact with a power line, or a broken strand | The rope is not used until it is replaced, or the damaged section is removed (not an option after power line contact) |
Source: 29 CFR 1926.1413(a).
Broken Wire Limits
| Rope | Deficient when it has |
|---|---|
| Running wire rope | 6 randomly distributed broken wires in one rope lay, or 3 broken wires in one strand in one rope lay |
| Rotation-resistant rope | 2 randomly distributed broken wires in 6 rope diameters, or 4 in 30 rope diameters |
| Pendants and standing rope | More than 2 broken wires in one rope lay beyond the end connections, or more than 1 in a rope lay at an end connection |
A rope lay is the length along the rope in which one strand makes one complete turn around the rope.
Who Inspects, and How Often
Each shift: a competent person looks at the running and standing rope likely to be used that shift. Untwisting or booming down is not required for this inspection.
Monthly: the same inspection, documented.
Annual: a qualified person inspects the whole length, with particular attention to sections hidden during shift and monthly inspections, rope at flange points and crossover points on drums, rope at reverse bends, and rope passing over sheaves.
Birdcaging is the outer strands opening up into a cage shape, usually after sudden release of a load or from the rope being forced through a tight sheave. It is a Category I deficiency.
5 Practice Questions: Wire rope inspection
From the question bank in the app. Pick an answer, then open the explanation. For a scored test, try the NCCCO core practice test.
Wire Rope
1. A running wire rope must be removed from service when you find…
- A6 broken wires in one lay or 3 in one strand
- BAny single broken wire
- CSurface rust of any kind
- DA kink that was straightened
Show answer
Answer: A. 6 broken wires in one lay or 3 in one strand. Removal criteria: 6 randomly distributed broken wires in one rope lay, or 3 in one strand in one lay.
Wire Rope
2. Kinking, birdcaging, crushing, and signs of core failure belong to which wire rope deficiency category?
- ACategory I (significant distortion)
- BCategory II (broken wires and diameter reduction)
- CCategory III (significant deficiencies other than distortion)
- DCategory IV (corrosion and heat damage)
Show answer
Answer: A. Category I (significant distortion). Category I covers significant distortion of the rope structure, which includes kinking, birdcaging, crushing, unstranding, and core failure.
Wire Rope
3. Under OSHA 1926.1413, broken wires and reduction of rope diameter make up which deficiency category?
- ACategory II
- BCategory I
- CCategory III
- DCategory IV
Show answer
Answer: A. Category II. Category I is significant distortion, Category II is broken wires and diameter reduction, and Category III is significant deficiencies other than distortion.
General Knowledge
4. According to OSHA 1926.1413, how many randomly distributed broken wires in rotation resistant rope are cause for replacement?
- A2 broken wires in 6 rope diameters
- B2 broken wires in 30 rope diameters
- C1 broken wire in 6 rope diameters
- D3 broken wires in one strand in one lay
Show answer
Answer: A. 2 broken wires in 6 rope diameters. OSHA 1926.1413 requires replacing rotation resistant rope with two randomly distributed broken wires in six rope diameters (or four in thirty).
Wire Rope
5. A standing rope (pendant) must be removed from service when a rope lay AT an end connection has how many broken wires?
- AMore than one
- BMore than two
- CMore than six
- DAny single broken wire
Show answer
Answer: A. More than one. Pendants are deficient with more than one broken wire in a rope lay located at an end connection.
Study the Whole Exam, Not 20 Questions
5,000+ practice questions across Core and every specialty, load chart trainers with the rating table on screen, timed exam simulations, and the pass guarantee.
Wire rope inspection: Questions & Answers
How many broken wires are allowed in crane wire rope?
Who inspects wire rope on a crane?
What is birdcaging in wire rope?
What if the rope has touched a power line?
How much diameter loss takes a rope out of service?
This page is a study aid. It summarizes federal OSHA rules and industry standards and is not a substitute for the regulation, the manufacturer's manual or your employer's procedures. State plans and site rules can be stricter.